 AWM90000 Series
Mass flow sensor for gases
FEATURES * Ranges 0...200 sccm1 or 0...2 "H2O (0...5 mbar) * Bidirectional sensing * Actual mass flow sensing * Low differential pressure sensing
SERVICE
To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through the sensor
SPECIFICATIONS
Maximum ratings Supply voltage2 8 to 15 V typ. 10 0.01 V 50 mW
ELECTRICAL CONNECTION
Power consumption Temperature limits Operating Storage Mechanical shock
-25 to 85C -40 to 90C 100 g (5 drops, 6 axes)
1
2
3
4
5
6
7
8
Note: 1 sccm denotes standard cubic centimeters per minute 2 Output voltage is ratiometric to supply voltage
December 2007 / 592
1/6
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
FLOW SENSOR CHARACTERISTICS3
VS = 10 0.01 V, TA = 25C
Part no. AWM92100V AWM92200V Flow range (full scale) 200 sccm 2 "H2O Pressure range Max. flow change4 5.0 l/sec 5.0 l/sec Output voltage @ trim point 77 mV @ 200 sccm 38 mV @ 2 "H2O
PERFORMANCE CHARACTERISTICS
VS = 10 0.01 V, TA = 25C
Characteristics
Zero offset Repeatability and hysteresis (combined) Ratiometricity error2 Temperature effects5 Offset Span -25 to 85 C6 -25 to 25 C 25 to 85 C AWM92100V AWM92200V AWM92100V AWM92200V Sensor resistance (pin 1 - pin 2, pin 1 - pin 8) Sensor current Response time Common mode pressure AWM92100V AWM92200V
Min.
-15
Typ.
0 0.1 0.30 2.07 -3.0 25
8 5
Max.
15 0.35
Unit
mV %FSO % reading mV %FSO % reading %FSO % reading
1.08 -30 1.5
5
1.75 1.0
2.2 0.6 3.0 25
kOhm mA ms p si
Notes: 2 Output voltage is ratiometric to supply voltage 3 A 5 micron filter is recommended for all devices. 4 Maximum allowable rate of flow change to prevent damage. 5 Temperature shifts in differential pressure devices are mostly due to the density change of the gas over temperature. 6 Shift is relative to 25 C. 7 Assumes low TCR bridge resistance used (pins 2 and 8). 8 Requires recommended Rc value of 1K Ohm is used (pins 3 to 7) and typ. heater control circuit. Maximum current Rh.
2/6
December 2007 / 592
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
OUTPUT FLOW VS INTERCHANGEABILITY
VS = 10 0.01 V, TA = 25C
OUTPUT CURVES
December 2007 / 592
3/6
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
HEATER CONTROL CIRCUIT
6 Rb 7 1 kOhm 3 Rr 4 Ra 5 Rh
SENSING BRIDGE SUPPLY CIRCUIT
10 V 24.9 kOhm 24.9 kOhm
A)
B)
2
8
1
Note: Circuits required for operation per specifications. Circuits are not on board the sensor. A) Customer supplied 1 kOhm resistor (affects temperature compensation and span voltage). B) Customer supplied 24.9 kOhm matched bridge resistors (affects null output voltage). Output is measured differentially from pins 8 to 2.
HEATER CONTROL CIRCUIT (suggested)
DIFFERENTIAL INSTRUMENTATION AMPLIFIER CIRCUIT (OPTIONAL)
2 R + R1 R4 (V2 - V1 ) + VOffset VO = 2 R R 1 3 R6 where VOffset = VS R +R 5 6
4/6 December 2007 / 592
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
OUTLINE DRAWING
13.08 (0.515)
8x3.05 (0.12)
7x2.54 (0.10)
8x0.51 (0.02)
8x0.25 (8x0.01)
15.75 (0.62)
17.02 (0.67) 1.02 (0.04) 32.39 (1.28)
12.57 (0.50)
27.94 (1.10) 1.14 (0.05)
2x O 1.17 (2x O 0.05) 13.21 (0.52)
2.79 (0.11)
O 3.81 (O 0.15)
2x O 4.70 (2x O0.19) 10.41 (0.41)
19.3 (0.76) 30.48 (1.20)
mass: approx. 5.6 g
dimensions in mm (inches)
December 2007 / 592
5/6
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
GAS CORRECTION FACTORS9
Gas type Helium (He) Hydrogen (H2) Argon (Ar) Nitrogen (N2) Oxygen (O2) Ai r Nitric oxide (NO) Carbon monoxide (CO) Methane (CH4) Ammonia (NH3) Nitrous oxide (N2O) Nitrogen dioxide (NO2) Carbon dioxide (CO2) Correction factor (approx.) 0.510 0.710,11 0.95 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.35 1.35 1.35
Notes: 9 Gas correction factors are referenced to nitrogen (N2) as calibration gas type. Approximate gas correction factors are provided as guidelines only. Individual gas types may perform differently at temperature extremes and varying flow rates. 10 When sensing Hydrogen (H2) or Helium (He) it may be necessary to power the mass flow sensor using increased supply voltage: Hydrogen typ. 12 V, Helium typ. 15 V 11 Hydrogen (H2) flow measurement requires the use of a special sensor. These devices provide normal operation when sensing hydrogen flow and are designated with an "H" at the end of the order number.
ORDERING INFORMATION
Flow range 200 sccm Dry gas AWM92100V
Pressure range 2 "H2O (5 mbar)
Dry gas AWM92200V
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
6/6
December 2007 / 592
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of AWM92200V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X